Mon–Fri 9–5 ET · Nationwide crews
Electronic access control readers beside a secured door

Electronic Access & Credentials

Access Control

Know who opened which door, when, and revoke it in seconds, without re-keying a building because one badge went missing.

Overview

Keys do not scale. Credentials do.

A mechanical key gives you no record and no recall. One lost key can mean re-coring an entire floor. Electronic access control replaces that with a credential you can issue, schedule, restrict by door and time, audit, and switch off remotely the moment someone leaves.

Wiscom designs access systems door by door: the right lock hardware for the door type and its fire rating, the right reader for your credential strategy, and controller capacity with room to grow. Life safety comes first: free egress, fire alarm release and ADA operation are designed in, not bolted on after inspection.

We deploy cloud-managed and on-premise platforms, integrate with video so every door event has a matching clip, and can bring an existing panel-based system into a modern interface without replacing every reader on day one.

Access Control installed by Wiscom Services Inc.

Where we deploy it

  • Corporate offices
  • Schools & districts
  • Healthcare & clinics
  • Multi-family & MDU
  • Warehouse & logistics
  • Data centers
  • Government facilities
  • Cannabis & regulated

Talk to an estimator

Send us drawings, a device count, or just the square footage, and we’ll tell you what the scope realistically looks like.

Capabilities

What this service actually includes.

Not a category heading, but the specific work we self-perform under it.

Readers & credentials

Encrypted smart cards and fobs, mobile credentials over Bluetooth and NFC, PIN keypads, biometric readers and multi-factor doors for high-security areas. We migrate legacy 125 kHz Prox to encrypted 13.56 MHz.

Door hardware

Electric strikes, magnetic locks, electrified levers and mortise locks, wireless locksets, door position switches, request-to-exit devices, delayed egress and automatic operators for ADA openings.

Controllers & software

Cloud-managed and on-premise controllers with scheduling, lockdown, anti-passback, first-person-in, multi-site administration and role-based operator permissions.

Gates, elevators & turnstiles

Vehicle gate operators, loop and credential entry, elevator floor-by-floor control, optical and full-height turnstiles, mantraps and controlled vestibules.

Video & alarm integration

Door-forced and door-held-open alarms tied to camera clips, badge-in snapshots, and a single investigation timeline across access, video and intrusion events.

Visitor & contractor management

Self-service check-in, host notification, temporary credentials that expire on their own, watchlist screening and printed badges with photo and access level.

Specification

How we decide what to specify.

The reference table our estimators and engineers work from when scoping this service.

CredentialSecurityUser experienceBest fit
125 kHz ProxLow: trivially clonedFamiliar, cheap to replaceLegacy systems awaiting migration
Encrypted smart cardHigh: mutual authenticationTap and goMost commercial buildings
Mobile credentialHigh: device-bound, revocablePhone stays in pocketOffices, tech, multi-tenant, MDU
PIN keypadMedium: codes get sharedNo card to carryBack doors, storage, secondary areas
BiometricVery high: non-transferableNothing to carry or loseServer rooms, pharmacy, cash and evidence
Multi-factorHighestDeliberately slowerVaults, data halls, regulated storage

Close-out

What you receive when we’re done.

Documentation is part of the scope, not a favor. Every access control project closes out with the same package, so the next person to touch the system, whether that is us or somebody else, can work from facts.

Ask for this list on every bid you receive. A contractor who cannot produce test results and as-builts is asking you to trust that the work was done right.
  • Door schedule listing hardware, reader and mode per opening
  • Access level and schedule matrix built with your team
  • Fire alarm interface verified with the AHJ present
  • Administrator training plus a written quick-reference guide
  • Credential enrollment and a clean starting cardholder database
  • Battery-backed operation confirmed under simulated power loss

FAQ

Access Control: common questions

It depends on the occupancy, the egress path and your local code. Maglocks require a compliant release method and must drop on fire alarm and loss of power. We design to IBC/NFPA 101 and confirm the approach with your authority having jurisdiction before we install. It is far cheaper than failing inspection.

Often yes, if they speak a supported protocol. That said, if you are still on unencrypted 125 kHz Prox we will recommend migrating: those credentials can be cloned with a device that costs less than a tank of gas. Many controllers support both during a phased cut-over.

Controllers and locks run on battery backup, typically four hours or more. Fail-safe doors on the egress path release as code requires; fail-secure doors stay locked but always allow exit from the inside by mechanical means. We test this with you at commissioning.

Yes. Lockdown can be triggered from software, a badge gesture, a physical button or a mobile app, and can be scoped to one wing or the whole campus. We build and rehearse the lockdown plan with your team as part of commissioning.

Free estimate · No obligation

Let’s scope your project.

Tell us what the building has to do. We’ll walk the site, design the system around it and give you a written estimate with no line items you can’t explain.

  • Site survey before we quote, not after
  • Written scope so you can compare bids honestly
  • One accountable contractor across every low voltage trade
Request a free estimate (470) 420-8885 Email the team

Mon–Fri 9:00am–5:00pm ET · HQ in Doraville, GA · Crews nationwide

Call Free Estimate